Build 3.1.128

<< Click to Display Table of Contents >>

Navigation:  Release Notes >

Build 3.1.128

Previous pageReturn to chapter overviewNext page

 

Release date: Dec 19th 2017

 

Fixes and improvements:

 

General:

Added a setting to specify what date to use when the date isn't set (which used to be 1970) SETTINGS.INI [Settings] DateNotSet=xxx
While in Edit Mode (offline) it sometimes did not go online after choosing 'Enable All' from the 'Online Features' menu

 

Trend Charts:

On a Trend Chart which had pens that were 'disabled' the values between the cursors failed to be calculated correctly and could cause a crash
When 'Setup Chart' is disabled on the Trend Chart menu via Passwords, the Setup button still worked
Passwords for Chart Notes were case sensitive, whereas normal passwords aren't, they have been made not case sensitive
If an 'Auto Chart Note' is associated with a pen whose variable has been deleted, then could crash
Protected against a crash when unable to display a Trend Chart popup menu
Trend charts with Auto Chart Notes could occasionally lockup

 

Logging:

DateTime Variables were not available for selection in Log Report Format in other languages

 

Passwords:

If a Config with Passwords enabled failed to open a COM port then a spurious network timeout message was shown

 

Historical Replay:

The Historical Replay Control panel did not remember its position

 

Strategy:

If an Event was set to watch an instrument parameter on a COM port that cannot be opened, then an 'Enable on Bool' would trigger that event incorrectly

 

Networking:

Enhancements to Local/Remote where more than 10 Remotes are connecting
Local could lockup when sending Alarm updates to remotes on a heavily loaded system

 

Watlow:

Watlow F4T: Boolean and module auto-detect enhancements
Watlow F4T: Added UI Modules
Watlow F4 & F4P: Changed Profile Number to Edit Profile Number
Watlow F4 Prog - Renamed Run to Running
Watlow F4: Added Alarm DI and DO Names
Watlow EZ Profiling Modbus added time for each step using F4TTime. H, M & S left in place

 

Honeywell:

Honeywell UDC2500: Added further parameters
Honeywell HC900: Added Write to Flash in HC900 instrument

 

Mitsubishi:

Mitsubishi-A driver failed on fast computers to recognize the CRC

 

Eurotherm:

Eurotherm Nanodac: Added instrument for Batch
Eurotherm Mini8: Fixed data type for fixed IO A & B >> bit from whole word

 

Yokogawa:

UP100P series: Fixed Modbus addressing errors and added program parameters

 

Anafaze:

Anafaze R/S: Changed .INI file to remove auto-detect

 

Ramp/Soak driver:

Changed 'End' to 'Process Complete'. Added 0=N/A to Jump To