Release date: Dec 19th 2017
Fixes and improvements:
General:
| • | Added a setting to specify what date to use when the date isn't set (which used to be 1970) SETTINGS.INI [Settings] DateNotSet=xxx |
| • | While in Edit Mode (offline) it sometimes did not go online after choosing 'Enable All' from the 'Online Features' menu |
Trend Charts:
| • | On a Trend Chart which had pens that were 'disabled' the values between the cursors failed to be calculated correctly and could cause a crash |
| • | When 'Setup Chart' is disabled on the Trend Chart menu via Passwords, the Setup button still worked |
| • | Passwords for Chart Notes were case sensitive, whereas normal passwords aren't, they have been made not case sensitive |
| • | If an 'Auto Chart Note' is associated with a pen whose variable has been deleted, then could crash |
| • | Protected against a crash when unable to display a Trend Chart popup menu |
| • | Trend charts with Auto Chart Notes could occasionally lockup |
Logging:
| • | DateTime Variables were not available for selection in Log Report Format in other languages |
Passwords:
| • | If a Config with Passwords enabled failed to open a COM port then a spurious network timeout message was shown |
Historical Replay:
| • | The Historical Replay Control panel did not remember its position |
Strategy:
| • | If an Event was set to watch an instrument parameter on a COM port that cannot be opened, then an 'Enable on Bool' would trigger that event incorrectly |
Networking:
| • | Enhancements to Local/Remote where more than 10 Remotes are connecting |
| • | Local could lockup when sending Alarm updates to remotes on a heavily loaded system |
Watlow:
| • | Watlow F4T: Boolean and module auto-detect enhancements |
| • | Watlow F4T: Added UI Modules |
| • | Watlow F4 & F4P: Changed Profile Number to Edit Profile Number |
| • | Watlow F4 Prog - Renamed Run to Running |
| • | Watlow F4: Added Alarm DI and DO Names |
| • | Watlow EZ Profiling Modbus added time for each step using F4TTime. H, M & S left in place |
Honeywell:
| • | Honeywell UDC2500: Added further parameters |
| • | Honeywell HC900: Added Write to Flash in HC900 instrument |
Mitsubishi:
| • | Mitsubishi-A driver failed on fast computers to recognize the CRC |
Eurotherm:
| • | Eurotherm Nanodac: Added instrument for Batch |
| • | Eurotherm Mini8: Fixed data type for fixed IO A & B >> bit from whole word |
Yokogawa:
| • | UP100P series: Fixed Modbus addressing errors and added program parameters |
Anafaze:
| • | Anafaze R/S: Changed .INI file to remove auto-detect |
Ramp/Soak driver:
| • | Changed 'End' to 'Process Complete'. Added 0=N/A to Jump To |